KNOWLEDGE / EDITORIAL ARCHIVE

Geothermal energy in homes: how an installation works

2026.11.23 / Pedro J. Hernández

A geothermal installation for housing uses a heat pump to exchange energy with the ground and produce heating, cooling and, depending on the system, domestic hot water. It does not generate electricity nor does it need to find high-temperature water: it takes advantage of the relative thermal stability of the subsoil through buried collectors.

Shallow geothermal can offer stable performance, but it is not automatically the best solution for any plot. Its feasibility depends on the building loads, the terrain, the available space, the drilling, the emission system, the annual use and the necessary investment.

Shallow geothermal and deep geothermal are not the same

The term geothermal encompasses very different applications:

  • Deep geothermal: It takes advantage of resources at elevated temperatures for direct thermal uses or, when conditions allow, electrical generation.
  • Shallow or very low enthalpy geothermal energy: It exchanges heat with the nearby layers of the ground and normally works together with a heat pump to air condition buildings.

In a geothermal house the second is used. The installation does not extract steam to drive a turbine. The land acts as an energy source in winter and as a sink in summer, while the heat pump raises or reduces the thermal level to that required by the building.

Geothermal installation scheme with horizontal and vertical collection and distribution through underfloor heating
Basic scheme of horizontal and vertical geothermal collection connected to a heat pump and an air conditioning system. Original source of the historical image: Soliclima.

How a geothermal installation works

The system can be divided into four parts:

  1. Geothermal capture: Buried pipes exchange energy with the ground or, in an open system, with groundwater.
  2. Heat pump: It transfers energy between the collection circuit and the building circuit through a refrigeration cycle.
  3. Interior distribution: radiant-cooling floors, fan coils, air treatment units or other emitters deliver or remove heat from spaces.
  4. Regulation and accumulation: Controls, pumps, tanks and valves coordinate temperatures, flows, schedules and DHW production when applicable.

In heating, the system takes energy from the ground and delivers it to the building. In reversible cooling, it extracts heat from the building and dissipates it underground. Some designs allow passive cooling or free cooling, using the land with reduced auxiliary consumption when the available temperatures are adequate.

Types of geothermal capture

Closed-circuit vertical collection

One or more probes are executed in which sealed probes are introduced. A fluid—usually water with antifreeze when necessary—circulates inside without coming into contact with the ground. It occupies little surface area, but requires drilling, study of geology and specialized execution.

Closed-circuit horizontal collection

The pipes are buried at a shallower depth, occupying a larger surface area. It can reduce the cost of drilling when the plot has free space, although its behavior is more influenced by surface conditions, soil humidity, vegetation and future earthworks.

Thermoactive foundations

The exchange pipes are integrated into piles, slabs or other foundation elements designed for this purpose. Coordination between structure, geotechnics and installation must be carried out from the first phases of the project.

open circuit

It uses groundwater captured by well and returns it in accordance with the design and applicable authorizations. It requires knowing flow rate, water quality, behavior of the aquifer, risks of incrustation or corrosion and administrative conditions. Not to be confused with a closed probe.

The ground is not always at 17 °C

A common simplification is to assign a single temperature to the subsurface. In reality, it depends on the location, depth, thermal conductivity, humidity, water flow, geology and thermal history of the catchment field.

At sufficient depth the daily and seasonal oscillation with respect to the outside air is reduced, providing more stable conditions for the heat pump. However, sizing cannot be based solely on an average temperature: you must check how much heat will be extracted and rejected throughout the year and how the terrain will evolve during its useful life.

What performance can it have?

The instantaneous performance of a heat pump is expressed by COP in heating and EER in cooling. To evaluate a real installation, the seasonal behavior is more interesting, which incorporates variations in load, temperatures, circulation pumps, controls and hours of use.

Geothermal can work with more stable exchange temperatures than an aerothermal heat pump, but it also requires electricity. Its renewable fraction depends on the average seasonal yield and regulatory conditions; It should not be presented as free energy.

Low temperature emitters, such as underfloor heating, usually improve heating performance. For cooling, humidity and surface temperature must be checked to avoid condensation. Fan coils allow sensitive load control and, depending on the design, dehumidification.

What should be studied before installing geothermal

  • Building demand: heating and cooling loads, DHW, schedules and simultaneity.
  • Passive design: insulation, tightness, orientation and sun protection They must first reduce demand.
  • Terrain: stratigraphy, conductivity, humidity, groundwater and ease of drilling.
  • Plot: available surface, machinery access, separations, existing constructions and future expansions.
  • Annual balance: energy extracted and rejected to avoid progressive thermal drift of the field.
  • Interior system: delivery temperatures, emitters, ventilation, humidity control and DHW production.
  • Electricity: available power, heat pump consumption and auxiliary equipment.
  • Processing: construction permits, drilling, subsoil occupation and, when groundwater exists, specific authorizations.
  • Maintenance: accessibility, pressure and flow control, fluid quality, filters, pumps and regulation.

In vertical fields of a certain magnitude, a thermal response test may be necessary to characterize the terrain. The IDAE technical guide on closed-circuit geothermal exchange systems develops design, installation and maintenance criteria.

Advantages of a geothermal house

  • Relatively stable performance against sudden changes in outside temperature.
  • Possibility of heating, cooling and DHW through a coordinated system.
  • Absence of an outdoor unit exchanging heat directly with the air.
  • Good compatibility with low temperature systems.
  • Buried catchment field with a potentially long useful life if well designed and implemented.

Limitations and risks

  • Initial investment and drilling cost higher than simpler solutions.
  • Need for space, access and sufficient knowledge of the terrain.
  • Difficulty in correcting an undersized catchment field once executed.
  • Electrical consumption and dependence on the real performance of the heat pump.
  • Possible long-term thermal imbalances if extraction and rejection are not studied together.
  • Processing and hydrogeological conditions in open catchments.

The comparison must be made against specific alternatives, not against an ideal installation. In some homes, a well-designed air source heat pump may be simpler and more economical; In others, geothermal provides sufficient stability, integration and performance to justify the investment.

Geothermal, aerothermal and solar thermal

Geothermal and aerothermal use heat pumps, but they exchange energy with different media: ground or outside air. The solar thermal energy, on the other hand, uses collectors to transform solar radiation into heat.

These technologies can be combined, but adding systems does not guarantee greater efficiency. Temperatures, accumulation, priority of sources, control and maintenance must be coordinated to avoid duplication and inefficient operation.

Regulations and documentation

The project must justify the demand and consumption in accordance with the CTE DB HE. The conditions of design, execution, maintenance and inspection of thermal installations are framed in the Regulation of Thermal Installations in Buildings.

In addition, mining, water, environmental, urban regulations and regional and municipal ordinances or procedures may intervene. Documentation must be verified for the specific location and type of collection.

Frequently asked questions

Does geothermal generate electricity in a home?

It’s not usual. A home uses shallow geothermal energy through a heat pump for air conditioning and DHW. Electricity generation corresponds to deep and higher temperature geothermal resources.

Can geothermal energy be installed on any plot?

It is not always technically or economically convenient. You have to review land, space, access for drilling, thermal loads, permits and investment.

Is a geothermal installation useful for cooling?

Yes, using a reversible heat pump and a suitable interior system. In some cases, passive cooling can also be studied, always controlling humidity and condensation.

Is it better than aerothermal energy?

There is no universal answer. Geothermal offers stable exchange, but requires buried capture. Aerothermal energy simplifies exterior work, although its performance depends more on ambient air. The comparison must be made with real loads, costs and conditions.

Integrate geothermal energy into the project

The capture, the technical room and the emitters must be coordinated from the beginning with the structure, foundation, plot, facilities and architecture. If you are studying a new home or a renovation, I can assess its fit within a single-family home project or one comprehensive reform. To review a specific case, use the page contact.