The Givoni bioclimatic chart relates temperature and humidity to strategies for improving comfort inside a building. It helps you decide when to prioritise ventilation, thermal mass, solar gains, evaporative cooling, dehumidification or active systems.
QUICK ANSWER
What is the Givoni chart used for?
It is a tool for preliminary climate assessment. Plotting hourly data on a psychrometric chart shows which conditions recur, when comfort is likely and which strategies may improve indoor conditions.
What is the Givoni bioclimatic chart?
The Givoni chart is based on a psychrometric chart. This version shows dry-bulb temperature (°C) on the horizontal axis and water vapour pressure (mmHg) on the vertical axis. The curves represent relative humidity (%). Overlaid zones indicate approximate comfort ranges and bioclimatic strategies.
Its defining contribution is to account for the way a building modifies outdoor conditions before they reach its occupants. The envelope, thermal mass, ventilation, solar gains and environmental systems all affect how outdoor climate translates into indoor conditions.
A point outside the comfort zone does not automatically call for mechanical conditioning. First check whether the design can change indoor conditions through passive or mixed-mode strategies.
How to read the Givoni chart
- Collect representative climate data. Use hourly temperature and humidity values where possible, distinguishing seasons and times of day.
- Plot the points. Start from the temperature on the horizontal axis and move vertically to the corresponding relative humidity curve. The intersection represents the state of the air.
- Identify clusters. Recurring points reveal the prevailing conditions, such as cold, dry heat, humid heat or intermediate conditions.
- Compare them with the strategy zones. This version distinguishes winter and summer comfort, cross-ventilation, thermal mass with selective ventilation, evaporative cooling, humidification and passive solar systems. Dehumidification may be needed even though this version does not show a dedicated zone for it.
- Apply the reading to the project. Translate the strategy into decisions about orientation, openings, shading, insulation, materials, ventilation and systems.

The boundaries depend on the chart version, comfort criteria and assumptions. Use it for preliminary guidance and verify the building’s performance separately.
CAMPO/01 · MICRO LAB 001
Plot a climate condition.
Enter the dry-bulb temperature and relative humidity. The explorer calculates basic psychrometric properties and plots the air condition on a simplified chart. Use it as a preliminary reading before comparing the point with the strategies in this article.
Scope. Educational tool for preliminary assessment. The humidity ratio assumes a standard atmospheric pressure of 101.325 kPa. Givoni’s zones vary by version, assumptions and comfort criteria. Use separate energy simulation, regulatory checks and hourly climate analysis where required.
Main bioclimatic strategies
Cold conditions
The priority is generally to reduce heat losses and make use of beneficial gains through insulation, air leakage control, solar gains and thermal storage where appropriate.
Dry heat
Shading, thermal mass and night ventilation can help. Evaporative cooling may also be useful when humidity is low enough.
Humid heat
Shade and air movement are particularly important. In high humidity, ventilation may need to be combined with dehumidification or cooling.
Conditions can shift between zones in a single day. A morning may require heating, midday may be comfortable and evening may call for ventilation. Hourly data are therefore more useful than a single monthly average.
Example of interpreting a warm climate such as Murcia
For a house in Murcia, first plot hourly data from a representative weather station. If there are periods of dry heat with sufficiently cool nights, assess shading, reduced internal gains, thermal mass and night ventilation. This is an example of the reasoning. The chart contains no Murcia climate data and cannot quantify useful hours for each strategy.
In winter, the analysis may point to improving the envelope, reducing air leakage and making use of solar gains without compromising summer performance. The final design also depends on orientation, use, shadows, wind, existing construction and feasible interventions.
In a renovation, for example, relate the climate assessment to the condition of the envelope, thermal bridges, ventilation and the thermal properties of the materials. In a new home, the chart helps compare options from the earliest siting decisions.
Differences between the Givoni and Olgyay charts
Both relate climate to comfort and serve different purposes. The Olgyay bioclimatic chart starts from environmental conditions and human response, while Givoni considers expected indoor conditions and organises strategies on a psychrometric chart.
You can use both during preliminary analysis once you understand their assumptions and limitations.
Common mistakes when using the chart
- Plotting monthly average temperatures alone.
- Treating a zone as a prescribed solution.
- Applying the same chart without considering climate, use or occupant adaptation.
- Overlooking solar radiation, wind, shading and internal gains.
- Treating initial guidance as a formal energy or comfort assessment.
Frequently asked questions
Can the Givoni chart replace an energy simulation?
No. It is a tool for diagnosis and guidance. Verify important decisions with calculations, simulation, applicable codes and an assessment of the specific building.
Can you use monthly averages?
They give a first approximation but hide day-to-night variation. Hourly data make it easier to identify when each strategy is useful.
Does a point outside the comfort zone mean mechanical conditioning is required?
First check whether the envelope, shading, ventilation, thermal mass or solar gains can change indoor conditions before turning to active systems.
Want to apply bioclimatic design to a real project?
Climate assessment becomes useful when it informs decisions about orientation, the envelope, materials and systems. If you are planning a house or renovation, I can help incorporate these criteria from the early stages.